Technical Parameters
No. |
Item |
Unit |
Data |
1 |
Rated voltage (Ur) |
V |
12/24 |
2 |
High voltage fuse current (lr) |
A |
3.15A |
3 |
Transformer rated capacity |
kVA |
3~5 |
4 |
Rated short-time withstand voltage (Ud) |
kV |
50 |
5 |
Rated lightning impulse withstand voltage (Up) |
kV |
125 |
6 |
Mechanical life |
Class |
M1/M2 |
7 |
Isolation handcart status and position indication communication module Modous (RS485) |
- |
Optional |
8 |
Electric operation module |
- |
Optional |
Dimensions of 12kV
Rated current |
P |
A |
B |
C |
D |
E |
630A |
150 |
502 |
532 |
490 |
202 |
100 |
210 |
652 |
682 |
638 |
277 |
160 |
|
275 |
852 |
882 |
838 |
377 |
200 |
Dimensions of 24kV (For 1000width cabinet)
Dimensions of 24kV (For 800width cabinet)
12Kv / 24kV Isolating Trolley(Busbar Trolley, Disconnecting Trolley)
Application
The 24kV withdrawable isolated trolley has the characteristics of perfect design, compact structure, easy operation and excellent performance. The product conforms to IEC62271-102 “High-voltage switchgear and control equipment-Part 102 AC disconnectors and grounding switches”. Suitable for high-voltage central cabinets, suitable for air-insulated indoor withdrawable central switch cabinets, for the main circuit to be switched under no-load conditions, and the circuit breaker being repaired waiting for electrical isolation of electrical equipment from live lines It has a safe interlocking device with the door.
Technical Parameters
No. |
Item |
Unit |
Data |
1 |
Rated voltage (Ur) |
V |
12/24 |
2 |
Rated current (lr) |
A |
630/1250 |
3 |
Rated short-time withstand current (lk) |
kA |
25 |
4 |
Rated short-circuit duration (tk) |
s |
3 |
5 |
Rated short-circuit peak current (lp) |
kA |
65 |
6 |
Rated short-time withstand voltage (Ud) |
kV |
50 |
7 |
Rated lightning impulse withstand voltage (Up) |
kV |
125 |
8 |
Mechanical life |
Class |
M1/M2 |
9 |
Isolation handcart status and position indication communication module Modous (RS485) |
- |
Optional |
10 |
Electric operation module |
- |
Optional |
Dimensions of 12kV
Product detail pictures:
Related Product Guide:
Good quality comes 1st; assistance is foremost; business enterprise is cooperation" is our business enterprise philosophy which is regularly observed and pursued by our company for China Wholesale 33Kv Outdoor Vacuum Circuit Breaker Factory – 12kV/24kV PT Trolley – Greenpower, The product will supply to all over the world, such as: Haiti, Washington, Irish, we are fully determined to control the whole supply chain so as to provide quality products at competitive price in a timely manner. We are keeping up with the advanced techniques, growing through creating more values for our clients and society.