China Wholesale 40.5 Kv Sf6 Circuit Breaker Factory – 12kV/24kV PT Trolley – Greenpower
China Wholesale 40.5 Kv Sf6 Circuit Breaker Factory – 12kV/24kV PT Trolley – Greenpower Detail:
Technical Parameters
No. |
Item |
Unit |
Data |
1 |
Rated voltage (Ur) |
V |
12/24 |
2 |
High voltage fuse current (lr) |
A |
3.15A |
3 |
Transformer rated capacity |
kVA |
3~5 |
4 |
Rated short-time withstand voltage (Ud) |
kV |
50 |
5 |
Rated lightning impulse withstand voltage (Up) |
kV |
125 |
6 |
Mechanical life |
Class |
M1/M2 |
7 |
Isolation handcart status and position indication communication module Modous (RS485) |
- |
Optional |
8 |
Electric operation module |
- |
Optional |
Dimensions of 12kV
Rated current |
P |
A |
B |
C |
D |
E |
630A |
150 |
502 |
532 |
490 |
202 |
100 |
210 |
652 |
682 |
638 |
277 |
160 |
|
275 |
852 |
882 |
838 |
377 |
200 |
Dimensions of 24kV (For 1000width cabinet)
Dimensions of 24kV (For 800width cabinet)
12Kv / 24kV Isolating Trolley(Busbar Trolley, Disconnecting Trolley)
Application
The 24kV withdrawable isolated trolley has the characteristics of perfect design, compact structure, easy operation and excellent performance. The product conforms to IEC62271-102 “High-voltage switchgear and control equipment-Part 102 AC disconnectors and grounding switches”. Suitable for high-voltage central cabinets, suitable for air-insulated indoor withdrawable central switch cabinets, for the main circuit to be switched under no-load conditions, and the circuit breaker being repaired waiting for electrical isolation of electrical equipment from live lines It has a safe interlocking device with the door.
Technical Parameters
No. |
Item |
Unit |
Data |
1 |
Rated voltage (Ur) |
V |
12/24 |
2 |
Rated current (lr) |
A |
630/1250 |
3 |
Rated short-time withstand current (lk) |
kA |
25 |
4 |
Rated short-circuit duration (tk) |
s |
3 |
5 |
Rated short-circuit peak current (lp) |
kA |
65 |
6 |
Rated short-time withstand voltage (Ud) |
kV |
50 |
7 |
Rated lightning impulse withstand voltage (Up) |
kV |
125 |
8 |
Mechanical life |
Class |
M1/M2 |
9 |
Isolation handcart status and position indication communication module Modous (RS485) |
- |
Optional |
10 |
Electric operation module |
- |
Optional |
Dimensions of 12kV
Product detail pictures:
Related Product Guide:
Usually customer-oriented, and it's our ultimate focus on to be not only by far the most reliable, trustable and honest provider, but also the partner for our customers for China Wholesale 40.5 Kv Sf6 Circuit Breaker Factory – 12kV/24kV PT Trolley – Greenpower, The product will supply to all over the world, such as: Houston, Zambia, Honduras, Our faith is to be honest first, so we just supply high quality products to our customers. Really hope that we can be business partners. We believe that we can establish long time business relationship with each other. You can contact us freely for more information and pricelist of our products !
By Lesley from Finland - 2017.03.28 16:34
Good quality and fast delivery, it's very nice. Some products have a little bit problem, but the supplier replaced timely, overall, we are satisfied.
By Susan from Gabon - 2017.06.16 18:23