Technical Parameters
No. |
Item |
Unit |
Data |
1 |
Rated voltage (Ur) |
V |
12/24 |
2 |
High voltage fuse current (lr) |
A |
3.15A |
3 |
Transformer rated capacity |
kVA |
3~5 |
4 |
Rated short-time withstand voltage (Ud) |
kV |
50 |
5 |
Rated lightning impulse withstand voltage (Up) |
kV |
125 |
6 |
Mechanical life |
Class |
M1/M2 |
7 |
Isolation handcart status and position indication communication module Modous (RS485) |
- |
Optional |
8 |
Electric operation module |
- |
Optional |
Dimensions of 12kV
Rated current |
P |
A |
B |
C |
D |
E |
630A |
150 |
502 |
532 |
490 |
202 |
100 |
210 |
652 |
682 |
638 |
277 |
160 |
|
275 |
852 |
882 |
838 |
377 |
200 |
Dimensions of 24kV (For 1000width cabinet)
Dimensions of 24kV (For 800width cabinet)
12Kv / 24kV Isolating Trolley(Busbar Trolley, Disconnecting Trolley)
Application
The 24kV withdrawable isolated trolley has the characteristics of perfect design, compact structure, easy operation and excellent performance. The product conforms to IEC62271-102 “High-voltage switchgear and control equipment-Part 102 AC disconnectors and grounding switches”. Suitable for high-voltage central cabinets, suitable for air-insulated indoor withdrawable central switch cabinets, for the main circuit to be switched under no-load conditions, and the circuit breaker being repaired waiting for electrical isolation of electrical equipment from live lines It has a safe interlocking device with the door.
Technical Parameters
No. |
Item |
Unit |
Data |
1 |
Rated voltage (Ur) |
V |
12/24 |
2 |
Rated current (lr) |
A |
630/1250 |
3 |
Rated short-time withstand current (lk) |
kA |
25 |
4 |
Rated short-circuit duration (tk) |
s |
3 |
5 |
Rated short-circuit peak current (lp) |
kA |
65 |
6 |
Rated short-time withstand voltage (Ud) |
kV |
50 |
7 |
Rated lightning impulse withstand voltage (Up) |
kV |
125 |
8 |
Mechanical life |
Class |
M1/M2 |
9 |
Isolation handcart status and position indication communication module Modous (RS485) |
- |
Optional |
10 |
Electric operation module |
- |
Optional |
Dimensions of 12kV
Product detail pictures:
Related Product Guide:
With our leading technology as well as our spirit of innovation,mutual cooperation, benefits and development, we will build a prosperous future together with your esteemed company for China Wholesale 4000 Amp Air Circuit Breaker Manufacturer – 12kV/24kV PT Trolley – Greenpower, The product will supply to all over the world, such as: Comoros, Afghanistan, Maldives, During the development, our company has built a well-known brand. It is well highly acclaimed by our customers. OEM and ODM are accepted. We are looking forward to customers from all over the world to join us to a wild cooperation.
By Bertha from Namibia - 2018.06.19 10:42
The company keeps to the operation concept "scientific management, high quality and efficiency primacy, customer supreme", we have always maintained business cooperation. Work with you,we feel easy!
By Madeline from Croatia - 2017.04.18 16:45