Ambient Condition
1) Ambient temperature: -25℃~+45℃, daily average: ≤35℃
2) Altitude: 1000m(Standard); can up to 4500m for special ordering;
3) Relative humidity: daily average ≤95%, monthly average ≤90%;
4) Earthquake intensity ≤8 degree;
5) Applicable occasions should be free from inflammables, explosives, corrosives and severe vibration.
Main Technical Parameters of Gpvc Vacuum Contactor-fuse Combination Apparatus
Items |
Unit |
Data |
|||
Rated Voltage |
kV |
3.6 |
7.2 |
12 |
|
1min Power frequency withstand voltage |
kV |
20 |
32 |
42 |
|
Lighting impulse withstand voltage |
kV |
46 |
60 |
75 |
|
Rated current |
A |
400 |
315 |
200 |
|
Rated short-time withstand current (4s) |
kA |
4 |
|||
Rated peak withstand current |
kA |
10 |
|||
Expected short-circuit breaking current |
kA |
50 |
|||
Expected short-circuit close current |
kA |
130 |
|||
Main circuit resistance |
uΩ |
≤250+RFuse |
|||
Max. transfer current |
A |
4000 |
4000 |
3200 |
|
Rated current breaking times |
times |
250,000 |
|||
Mechanical life |
Mechanical hold-type |
times |
300,000 |
||
Electrical hold-type |
times |
500,000 |
|||
Main circuit resistance |
uΩ |
≤150 |
Plan of the Gpvc Vacuum Contactor-fuse Combination
Plan number |
Plan -1 |
Plan – 2 |
|
Primary plan |
|||
|
Rated current (A) |
~400 |
~400 |
Main components |
Vacuum contactor-Fuse combination – GPVC |
1 |
1 |
Current transformer LZZBJ |
3 |
3 |
|
Voltage transformer JDZ10 or JDZX10 |
|
|
|
High voltage fuse XRNM-10 |
3 |
3 |
|
Earthing switch GPJN15-12 |
|
1 |
|
Voltage monitor device |
As Users requirement |
As Users requirement |
|
Remarks |
Motor driving |
Motor driving |
Outline dimension of gpvc Installed switchgear
Product detail pictures:
Related Product Guide:
Our primary purpose is to give our shoppers a serious and responsible company relationship, giving personalized attention to all of them for China Wholesale 40Ka Vacuum Circuit Breaker Factory – Vacuum Contactor Switch Fuse Combined Apparatus – Greenpower, The product will supply to all over the world, such as: Swiss, Kenya, Romania, Based on our automatic production line, steady material purchase channel and quick subcontract systems have been built in mainland China to meet customer's wider and higher requirement in recent years. We have been looking forward to cooperating with more clients worldwide for common development and mutual benefit!Your trust and approval are the best reward for our efforts. Keeping honest, innovative and efficient, we sincerely expect that we can be business partners to create our brilliant future!