China Wholesale Fixed Type Acb Manufacturers – Vacuum Contactor Switch Fuse Combined Apparatus – Greenpower
China Wholesale Fixed Type Acb Manufacturers – Vacuum Contactor Switch Fuse Combined Apparatus – Greenpower Detail:
Ambient Condition
1) Ambient temperature: -25℃~+45℃, daily average: ≤35℃
2) Altitude: 1000m(Standard); can up to 4500m for special ordering;
3) Relative humidity: daily average ≤95%, monthly average ≤90%;
4) Earthquake intensity ≤8 degree;
5) Applicable occasions should be free from inflammables, explosives, corrosives and severe vibration.
Main Technical Parameters of Gpvc Vacuum Contactor-fuse Combination Apparatus
Items |
Unit |
Data |
|||
Rated Voltage |
kV |
3.6 |
7.2 |
12 |
|
1min Power frequency withstand voltage |
kV |
20 |
32 |
42 |
|
Lighting impulse withstand voltage |
kV |
46 |
60 |
75 |
|
Rated current |
A |
400 |
315 |
200 |
|
Rated short-time withstand current (4s) |
kA |
4 |
|||
Rated peak withstand current |
kA |
10 |
|||
Expected short-circuit breaking current |
kA |
50 |
|||
Expected short-circuit close current |
kA |
130 |
|||
Main circuit resistance |
uΩ |
≤250+RFuse |
|||
Max. transfer current |
A |
4000 |
4000 |
3200 |
|
Rated current breaking times |
times |
250,000 |
|||
Mechanical life |
Mechanical hold-type |
times |
300,000 |
||
Electrical hold-type |
times |
500,000 |
|||
Main circuit resistance |
uΩ |
≤150 |
Plan of the Gpvc Vacuum Contactor-fuse Combination
Plan number |
Plan -1 |
Plan – 2 |
|
Primary plan |
|||
|
Rated current (A) |
~400 |
~400 |
Main components |
Vacuum contactor-Fuse combination – GPVC |
1 |
1 |
Current transformer LZZBJ |
3 |
3 |
|
Voltage transformer JDZ10 or JDZX10 |
|
|
|
High voltage fuse XRNM-10 |
3 |
3 |
|
Earthing switch GPJN15-12 |
|
1 |
|
Voltage monitor device |
As Users requirement |
As Users requirement |
|
Remarks |
Motor driving |
Motor driving |
Outline dimension of gpvc Installed switchgear
Product detail pictures:
Related Product Guide:
Like a result of ours specialty and repair consciousness, our enterprise has won a superb popularity amid buyers everywhere in the environment for China Wholesale Fixed Type Acb Manufacturers – Vacuum Contactor Switch Fuse Combined Apparatus – Greenpower, The product will supply to all over the world, such as: Pakistan, Barbados, Plymouth, We've a skilled sales team, they have mastered the best technology and manufacturing processes, have years of experience in foreign trade sales, with customers able to communicate seamlessly and accurately understand the real needs of customers, providing customers with personalized service and unique merchandise.
By Anna from Romania - 2018.06.12 16:22
Good quality, reasonable prices, rich variety and perfect after-sales service, it's nice!
By Joanna from Nicaragua - 2018.03.03 13:09