China Wholesale Lbs Factory – 12kV/24kV PT Trolley – Greenpower
China Wholesale Lbs Factory – 12kV/24kV PT Trolley – Greenpower Detail:
Technical Parameters
No. |
Item |
Unit |
Data |
1 |
Rated voltage (Ur) |
V |
12/24 |
2 |
High voltage fuse current (lr) |
A |
3.15A |
3 |
Transformer rated capacity |
kVA |
3~5 |
4 |
Rated short-time withstand voltage (Ud) |
kV |
50 |
5 |
Rated lightning impulse withstand voltage (Up) |
kV |
125 |
6 |
Mechanical life |
Class |
M1/M2 |
7 |
Isolation handcart status and position indication communication module Modous (RS485) |
- |
Optional |
8 |
Electric operation module |
- |
Optional |
Dimensions of 12kV
Rated current |
P |
A |
B |
C |
D |
E |
630A |
150 |
502 |
532 |
490 |
202 |
100 |
210 |
652 |
682 |
638 |
277 |
160 |
|
275 |
852 |
882 |
838 |
377 |
200 |
Dimensions of 24kV (For 1000width cabinet)
Dimensions of 24kV (For 800width cabinet)
12Kv / 24kV Isolating Trolley(Busbar Trolley, Disconnecting Trolley)
Application
The 24kV withdrawable isolated trolley has the characteristics of perfect design, compact structure, easy operation and excellent performance. The product conforms to IEC62271-102 “High-voltage switchgear and control equipment-Part 102 AC disconnectors and grounding switches”. Suitable for high-voltage central cabinets, suitable for air-insulated indoor withdrawable central switch cabinets, for the main circuit to be switched under no-load conditions, and the circuit breaker being repaired waiting for electrical isolation of electrical equipment from live lines It has a safe interlocking device with the door.
Technical Parameters
No. |
Item |
Unit |
Data |
1 |
Rated voltage (Ur) |
V |
12/24 |
2 |
Rated current (lr) |
A |
630/1250 |
3 |
Rated short-time withstand current (lk) |
kA |
25 |
4 |
Rated short-circuit duration (tk) |
s |
3 |
5 |
Rated short-circuit peak current (lp) |
kA |
65 |
6 |
Rated short-time withstand voltage (Ud) |
kV |
50 |
7 |
Rated lightning impulse withstand voltage (Up) |
kV |
125 |
8 |
Mechanical life |
Class |
M1/M2 |
9 |
Isolation handcart status and position indication communication module Modous (RS485) |
- |
Optional |
10 |
Electric operation module |
- |
Optional |
Dimensions of 12kV
Product detail pictures:
Related Product Guide:
We are experienced manufacturer. Wining the majority of the crucial certifications of its market for China Wholesale Lbs Factory – 12kV/24kV PT Trolley – Greenpower, The product will supply to all over the world, such as: Oman, Albania, Vancouver, Our market share of our products has greatly increased yearly. If you are interested in any of our products or would like to discuss a custom order, please feel free to contact us. We are looking forward to forming successful business relationships with new clients around the world in the near future. We are looking forward to your inquiry and order.
By Julia from Lisbon - 2018.09.08 17:09
We are long-term partners, there is no disappointment every time, we hope to maintain this friendship later!
By Lillian from Kuwait - 2018.09.29 17:23