China Wholesale Moulded Case Circuit Breaker Factory – GPVN-40.5kV Indoor AC High Voltage Vacuum Circuit Breaker – Greenpower
China Wholesale Moulded Case Circuit Breaker Factory – GPVN-40.5kV Indoor AC High Voltage Vacuum Circuit Breaker – Greenpower Detail:
Ambient Condition
Altitude: 1000m(Standard); can up to 4500m for special ordering;
Ambient temperature: -25℃ ~+45℃;
Relative humidity: daily average ≤95%, monthly average ≤90%;
Earthquake intensity: ≤8 degree;
Applicable occasions should free from inflammables, explosives, corrosives and severe vibration.
Model
Structure Feature
1. The arc-extinguish chamber is on the upper part and the mechanism is on the lower part. This structure is convenient for debug.
2. Complex insulating structure using air and organic material; Compact dimension and small weight.
3. Vacuum arc-extinguish chamber of Cutler-Hammer Company (USA) and domestic ZMD are both applicable for the VCB. Both two kinds of chambers extinguish arc by vertical magnetic field and featuring with low cut-off and good on-off capability with asymmetry.
4. Simple spring operation mechanism is free from maintenance within 10000 times of operations.
5. Lead-screw propeller, easy and stable operation and good self-locking capability.
Technical Specification
No. |
Item |
Unit |
Data |
1 |
Rated voltage |
kV |
36/38/40.5 |
2 |
1min. Power frequency withstand voltage |
kV |
95 (118, isolating distance) |
3 |
Lightning impulse withstand voltage(peak) |
kV |
185 (215 isolating distance) |
4 |
Rated current |
A |
630,1250,1600,2000, 2500 |
5 |
Rated short-circuit breaking current |
kA |
20, 25, 31.5 |
6 |
Rated short-circuit making current(peak) |
kA |
50, 63, 80 |
7 |
4s rated short-time withstand current |
kA |
20, 25, 31.5 |
8 |
Rated peak withstand current |
kA |
50, 63, 80 |
9 |
Rated operation sequence |
O-0.3s-CO -180s-CO |
|
10 |
Breaking times of rated short circuit breaking current |
Times |
30 |
11 |
Mechanical life |
Times |
10000; 20000 (for magnet type) |
12 |
Rated frequency |
Hz |
50/60 |
13 |
Rated breaking current of capacitor bank |
A |
400 |
Technical Specification Of Storage Motor Of Operating Mechanism
No. |
Rated voltage |
Rated output power |
Normal operate voltage |
|
HDZ-22301B |
DC110V AC110V |
DC220V AC220V |
≤230W |
85%-110% rated voltage |
Outline And Dimension Of Installation
Secondary Diagram
Product detail pictures:
Related Product Guide:
Our development depends on the advanced equipment ,excellent talents and continuously strengthened technology forces for China Wholesale Moulded Case Circuit Breaker Factory – GPVN-40.5kV Indoor AC High Voltage Vacuum Circuit Breaker – Greenpower, The product will supply to all over the world, such as: Manila, Mexico, Portugal, If you give us a list of merchandise you are interested in, along with makes and models, we can send you quotations. Remember to email us directly. Our goal is to establish long-term and mutually profitable business relationships with domestic and overseas clients. We look forward to receiving your reply soon.
By Arlene from Karachi - 2018.05.13 17:00
We have been cooperated with this company for many years, the company always ensure timely delivery ,good quality and correct number, we are good partners.
By Ellen from Holland - 2018.09.29 13:24