China Wholesale Smc Busbar Support Factory – 12/24/40.5kV Shutter Assembly And Interlocking – Greenpower
China Wholesale Smc Busbar Support Factory – 12/24/40.5kV Shutter Assembly And Interlocking – Greenpower Detail:
Shutter Assembly 5GP.320.010 Installation Diagram
(800mm width middle-placed switchgear)
Shutter Assembly 5GP.320.010 Arrangement List
No. |
Name |
Drawing no. |
Qty. (pc/set) |
1 |
Right supporting bracket |
8GP.123.011 |
1 |
2 |
Right connection plate |
5GP.235.011 |
1 |
3 |
Indicating tag |
8GP.866.014 |
1 |
4 |
Left connection |
5GP.235.010 |
1 |
5 |
Left supporting bracket |
8GP.123.010 |
1 |
6 |
Connection welding |
5GP.174.016.1(For VD4) |
2 |
5GP.174.016.2(For GPVN) |
|||
5GP.174.016.3(For VB2) |
|||
7 |
Down shutter gate |
8GP.320.010 |
1 |
8 |
Block jammed 8 |
DK-8 |
8 |
9 |
Bracket plate |
8GP.123.013 |
3 |
No. |
Name |
Drawing no. |
Qty. (pc/set) |
10 |
Connection welding |
5GP.174.017.1(For VD4, 40kA) |
2 |
5GP.174.017.2(For VD4, 31.5kA) |
|||
5GP.174.017.3(For GPVN) |
|||
5GP.174.017.4(For VB2) |
|||
11 |
Indicating tag |
8GP.866.012 |
1 |
12 |
Indicating tag |
8GP.866.013 |
2 |
13 |
Bracket plate |
8GP.123.012 |
3 |
14 |
Upper shutter |
8GP.320.011 |
1 |
15 |
Guide rod |
8GP.234.011(For VD4, GPVN) |
2 |
8GP.234.011.1(For VB2) |
|||
16 |
Stopper sleeve |
8GP.210.011 |
2 |
Other specification shutter arrangement list
Code |
5GP.320.010.1 |
5GP.320.010.2 |
5GP.320.010.3 |
5GP.320.010.4 |
5GP.320.010.5 |
Cabinet width |
650mm |
700mm |
840mm |
900mm |
1000mm |
Upper gate |
8GP.320.011.1 |
8GP.320.011.2 |
8GP.320.011.3 |
8GP.320.011.4 |
8GP.320.011.5 |
Down gate |
8GP.320.010.1 |
8GP.320.010.2 |
8GP.320.010.3 |
8GP.320.010.4 |
8GP.320.010.5 |
Shutter Assembly 5GP.320.011
(1000mm width middle-placed switchgear)
Shutter Mechanism Device 5GP.320.011 Arrangement List
(1000mm width middle-placed switchgear)
No. |
Name |
Drawing no. |
Qty. (pc/set) |
1 |
Right supporting bracket |
8GP.123.276 |
1 |
2 |
Right connection plate |
5GP.235.012 |
1 |
3 |
Indicating tag |
8GP.866.014 |
1 |
4 |
Left connection plate |
5GP.235.013 |
1 |
5 |
Left supporting bracket |
8GP.123.275 |
1 |
6 |
Connection weld assembly |
5GP.174.281 |
2 |
7 |
Down shutter |
8GP.320.273 |
1 |
8 |
Block jammed 10 |
DK-10 |
8 |
No. |
Name |
Drawing no. |
Qty. (pc/set) |
9 |
Bracket plate |
8GP.123.278 |
3 |
10 |
Connection welding joint |
5GP.174.282 |
2 |
11 |
Indicating tag |
8GP.866.012 |
1 |
12 |
Indicating tag |
8GP.866.013 |
2 |
13 |
Bracket plate |
8GP.123.277 |
3 |
14 |
Upper shutter |
8GP.320.274 |
1 |
15 |
Guide rod |
8GP.234.272 |
2 |
16 |
Stopper sleeve |
8GP.210.011 |
2 |
Other specification shutter arrangement list
Code |
5GP.320.011.1 |
5GP.320.011/JY |
5GP.320.011.2 |
5GP.320.011.3 |
Cabinet width |
800mm |
1000mm(Insulating) |
1100mm |
1200mm |
Upper gate |
8GP.320.274.1 |
5GP.320.275 |
8GP.320.274.2 |
8GP.320.274.3 |
Down gate |
8GP.320.273.1 |
5GP.320.275.1 |
8GP.320.273.2 |
8GP.320.273.3 |
Note: 5GP.320.275 is for insulating shutter by SMC plate in middle and both end by steel plate, other shutter assembly if need insulating gate please specify.
Earthing switch operation mechanism interlock device (For connection arm drive operation) 5GP.363.010.1 assembly diagram
Instruction of Interlock Device
The interlock device is added the reverse interlock with the rear door which designed on the basis of original 5GP.363.010 earthing switch operation mechanism interlock device. That is, after the earthing switch is closed and open the rear door (sealing plate), the original interlock could still operating the earthing switch, but this interlock could not. You must first shut the rear door (sealing plate) in order to operate the earthing switch.
The working principles of the interlock device is changed the No. 24 locking sleeve to what showed on right and added spring on the basis of the original 5GP .363.010. When the rear door (sealing plate) open, the lock sleeve enter into the square hole of the cabinet (recommended size 35X35), earthing switch cannot be operated.
Earthing switch operation mechanism interlock device (For connection arm drive operation)
5GP.363.010.1 arrangement list.
No. |
Name |
Drawing no. |
Qty. (pc/set) |
1 |
Bearing |
8GP.263.011 |
1 |
2 |
Sector |
8GP.192.010 |
1 |
3 |
Sector |
8GP.192.011 |
1 |
4 |
Axis sleeve |
8GP.210.014.1 |
2 |
5 |
Sector |
8GP.151.041 |
1 |
6 |
Axis sleeve |
8GP.211.061 |
1 |
7 |
Sector |
8GP.151.039 |
1 |
8 |
Axis sleeve |
8GP.211.062 |
1 |
9 |
Bolt M5×12 |
GB70-85 |
1 |
10 |
Sector |
8GP.151.042 |
1 |
11 |
Sector |
8GP.151.043 |
1 |
12 |
Operation rod |
8GP.200.013.1 (Long 1432 for cabinet depth 1500 depth) |
1 |
8GP.200.013.2 (Long 1590 for cabinet depth 1660) |
1 |
||
13 |
Supporting plate |
8GP.161.058 |
1 |
8GP.161.058.1(For option) |
1 |
No. |
Name |
Drawing no. |
Qty. (pc/set) |
14 |
Cover |
8GP.017.011.1 |
1 |
15 |
Bracket |
5GP.043.022 |
1 |
16 |
Supporting plate |
8GP.161.059 |
1 |
17 |
Slider |
8GP.143.010 |
2 |
18 |
Axis sleeve |
8GP.211.058 |
1 |
19 |
Stopper sleeve |
8GP.211.057 |
3 |
20 |
Support base |
8GP.043.019 |
1 |
21 |
Close indicating |
8GP.866.010 |
1 |
22 |
Connection rod assembly |
5GP.233.030.1 |
1 |
5GP.233.030.3(For option) |
1 |
||
23 |
Open indicating |
8GP.866.011 |
1 |
24 |
Locking sleeve |
8GP.211.201 |
1 |
25 |
Tooth plug plate |
8GP.151.044 |
1 |
26 |
Axis sleeve |
8GP.211.060 |
2 |
27 |
Tag |
8GP.860.010 |
1 |
28 |
Pressure spring |
8GP.282.201 |
1 |
29 |
Locking sleeve fixing Bolt |
8GP.920.002 |
1 |
Note:
1. No. 1~12 see the previous page.
2. No. 22 Connection rod assembly, the connection arm has two size: Cabinet center distance 60mm in common. If need 80mm center distance please check page 17 the connection arm assembly instruction, and specify when ordering.
Earthing switch operation mechanism interlock device (For bevel gear drive operation) 5GP.577.1001
Earthing switch operation mechanism interlock device (For bevel gear drive operation) 5GP.577.1001 arrangement list
No. |
Name |
Drawing no. |
Qty. (pc/set) |
1 |
Bearing |
8GP.263.011 |
1 |
2 |
Stopper plate |
8GP.151.084 |
2 |
3 |
Axis sleeve |
8GP.210.014.1 |
2 |
4 |
Sector |
8GP.151.041 |
1 |
5 |
Axis sleeve |
8GP.210.014.2 |
1 |
6 |
Bolt M 5X12 |
GB70-85 |
1 |
7 |
Sector |
8GP.151.042 |
1 |
8 |
Sector |
8GP.151.043 |
1 |
9 |
Axis sleeve |
8GP.210.014.3 |
1 |
No. |
Name |
Drawing no. |
Qty. (pc/set) |
10 |
Stopper sleeve |
8GP.210.322 |
1 |
11 |
Operation rod |
8GP.174.214 |
1 |
12 |
Cover |
8GP.017.011.2 |
1 |
13 |
Support base |
5GP.043.022 |
1 |
14 |
Slider |
8GP.143.010 |
2 |
15 |
Supporting plate |
8GP.161.059 |
1 |
16 |
Supporting plate |
8GP.161.058 |
1 |
17 |
Tooth plug plate |
8GP.151.044 |
1 |
18 |
Tag |
8GP.860.010 |
1 |
Note: 1. This mechanism need interlocked with down door, please specify when ordering.
Product detail pictures:
Related Product Guide:
High-quality comes 1st; support is foremost; business is cooperation" is our small business philosophy which is regularly observed and pursued by our organization for China Wholesale Smc Busbar Support Factory – 12/24/40.5kV Shutter Assembly And Interlocking – Greenpower, The product will supply to all over the world, such as: Belize, Los Angeles, Uruguay, because of our company has been persisting in the management idea of "Survival by Quality, Development by Service, Benefit by Reputation" . We fully realize the good credit standing, the high quality products, the reasonable price and the professional services are the reason that the customers choose us to be their long-term business partner.
By Michelle from Rotterdam - 2018.06.09 12:42
In China, we have many partners, this company is the most satisfying to us, reliable quality and good credit, it is worth appreciation.
By Julia from New Zealand - 2018.11.06 10:04