GPM2.1 Takotoranga Tuarua Kaitihi Kāpeke Kaiuru
Ko te GPM2.1 papanga taura hau parapara e GreenPower e whanangia ana he whakamahi i ngā taputapu toa whakaaetia, he papanga taura hau parapara huihuihia ki te whare putake. He tōtika ki te AC 50/60Hz, te tepe mahi mōrahi <660V, me ngā punaha whakahaere hau e 6300A me te iti ake, ka whakamahia hei whakarere i te hau, whakawhitinga, whakahaere, me te whakakaha hau whakarewa.
- Tirohanga
- Ngā Mea Whakamomori
Ko te GPM2.1 papanga taura hau parapara e GreenPower e whanangia ana he whakamahi i ngā taputapu toa whakaaetia, he papanga taura hau parapara huihuihia ki te whare putake. He tōtika ki te AC 50/60Hz, te tepe mahi mōrahi <660V, me ngā punaha whakahaere hau e 6300A me te iti ake, ka whakamahia hei whakarere i te hau, whakawhitinga, whakahaere, me te whakakaha hau whakarewa.
Ko te kauta tuarangi iti GPM2.1 he taputapu whakahaere e whai hāngai ana i te hangarau matua, pūmahara tōtika, hanganga tōtika, whakamahi maru, haumaru, me te whakapai. Kua whakamahia whānuitia i ngā pūnaha tukatuka hiko penei i te hiko, te hanga, te tōka paraihe, te whakapai paraihe, te kaihanga, me te hinu.

| Pūtāuta e pā ana | 380/440/660V |
| Tihoni whakariterite | 630~6300A |
| Akeake o te whakauru | 50\/60hz |
| Kaha taitea taitea | ka taea e te 1pk te whai 375kA |
| Ko te āhua IP | IP30 / IP32 / IP40 / IP54 |
| Te rōrahi whakauru | 660/1000V |

He tino pai te hanga me te tikanga hangahanga. Ko te rere tata, te kaha whakamutu, me te kaha whakapiri tō GPM2.1 kua whakawhanake ake i ētahi atu momo pāpaku taraweti, ā, he māmā te whakahaere, haumaru, me te whakapono.
He pai te mahi tiaki. Ko GPM2.1 he pāpaku tāwā, ā, kei te ōrite te wāhi roto ki te IEC439-1 "Form 3b" rānei "Form 4b" ina hokona ana, ā, ko te kaha tiaki o te takotoranga ko IP3X, IP31, IP32, IP4X, IP41, IP42, IP43, IP5X, IP54 ina hokona ana.
He tino whakamana te here. Ko te here kia kaua rawa e hara i ngā whakamāmātanga o GPM2.1 e whakawātea ana e te rereke tā te pāpaku me te rereke tā te pouaka tākarotia e herea ana. He tino tika me te rite te hoahoa, ā, ka taea te whakakaha i ngā hara katoa e āhua taea ana, ā, ka taea hoki te whakamahi i te tikanga whakahaere hei whakawhanake i te here ake i waenganui i ngā pouaka.
He nui ngā whakaritenga kei reira, ā, kua oti, ā, māmā te whakakotahi. Ko te GPM2.1 te wāhanga tātai ko te 8E, ā, ko ngā wāhanga mahi ko te 8E/4, 8E/2, 6E, 8E, 12E, 16E, 24E, 32E, 72E. Ka taea e tētahi kabinet MCC te whakauru i te maha o ngā wāhanga mahi e 36, ā, ka taea te whakamahinga. Ko te whakauru tātaritanga a PC me te MCC e whakarite ana i ngā tikanga pai hei whakaiti i te maha o ngā kabinet, me te whiriwhiri whakautu ngawari.
Ko te GPM2.1 tāpokopoko hau parakore he taputapu whakahaere e whai hāngai ai te hangarau, te whirinakitanga o te mahi, te hanga tūturu, te whakamahi ai, te haumaru, te whirinaki hoki. Kua whakamahia whānuitia ki ngā pūnaha tuku hau, pērā i te hāngai hau, te hanga whare, te tōka, te whakapai pāpaku, te kaihanga taonga, me te hinu.




Kei te whakarato a GreenPower i ngā whakaeke hiko toa. Whakapā atu ki a mātou inaianei kia rite ki te whakamātau me te tātata utu. Ko tā mātou kapa toa ka whakarato i a koe i te ratonga katoa me te tautoko hangarau i te rohe o te huringa.
Īmēra: [email protected]
Waea: +86-18989782765
Tākupehi: 057785500968