Tautuhinga rorohiko whakauru hau

Whārangi Tīmatanga >  Ngā Hua >  Raihana Whakauru Hiko Whakarewa >  Raihana Whakamau Kiriata

GPN2 40.5kV CGIS Cubicle Kaupeka Hauwhāwhā Whakauru

Ko te taputapu whakawhiti whakawātea hau-momo (Cubicle type gas-isolated switchgear) (CGIS) he taputapu whakawhiti hau-momo, whakakotahi-wheketere, whakakiihia ki te whakarewa, he momo pouaka-momo mo nga tono pahi kotahi, tae atu ki te Momo Green G

  • Tirohanga
  • Ngā Mea Whakamomori

Ko te taputapu whakawhiti whakawātea hau-momo (Cubicle type gas-isolated switchgear) (CGIS) he taputapu whakawhiti hau-momo, whakakotahi-wheketere, whakakiihia ki te whakarewa, he momo pouaka-momo mo nga tono pahi kotahi, tae atu ki te Momo Green G

Kua whanake a “Momo Kākāriki” GPN2N-40.5 kia whakamahi hau parakore hei kaiwhakamātau mō te huinga hua ki te hanganga kāore he whakamātautau hau SF6, e kaha ai te whakamarumaru i te taiao ki te kaitiaki hau parakore.

Ko te “Momo Kākāriki” GPN2E-40.5 te kaiwhakauru i ngā tikanga matua o te hau parakore (SF6+N2) me ngā kaitiaki wātea, e āki ai i te taputapu kia mahi i runga i tētahi ara e āwhina ai i te taiao.

Ko te GPN2S-40.5 "momo tūmau" he mea kua whakakīia katoa ki te SF6, he rawa hoki teitei me te whakamahi māmā. Ki te whakauru atu ki te hanga matihiko hōu me te whakamātau ake ake i te kaiwhakauru, te whakahaere me te hangarau whakamaru, he tōtika a CGIS ki ngā hiahia whakarere ika hiko. He tino tōtika a CGIS ki ngā umanga e hiahiatia ana kia tino whakapono pērā i ngā Ranga Hiko, Ngā Kōhanga, Te Waka Rere, Ngā Whare Parakore, Ngā Feremiana Hau me ngā Ranga Rere Waka.

Ko te tapa whakauru kua hoahoa hou hei ngā tikanga whakauru tūmatanui mō te tapa whakauru o rohe ki te GB 3906, DL/T404 me te IEC 62271-200.

Technical Parameters.png

Pūtāuta e pā ana 6~12kV
Tihoni waewae 50\/60hz
Tihoni whakariterite 630~4000A
Te kaha o te kaiwhakauru matua 1250, 1600, 2000, 2500, 4000A
Te kaha o te kaiwhakauru tātari 630, 1250, 1600, 2000, 2500, 3150A
Kaha tāpokai (4s) e taea ana 16, 20, 25, 31.5, 40, 50kA
Kaha taitea taitea 40, 50, 63, 80, 100, 125kA
Wāhi tapu Kōwhiti IP4X, IP2X (kuata VCB kua whakatuwhera)
Te āhua ake (Whānui × Pakaru × Teitei) 650(800, 1000)×1500(1300, 1670, 2000)×2300mm
Whakaaetanga Ka tutuki i ngā tānagata haumaru o te ao pērā i te ISO, IEEE

Product Advantages.png

Te haumaru teitei rawa atu mō te kaimahi me te taputapu: Ko te pēhi poto o te whare he 0.00MPa(20℃). Ko reira, me te nui ake o ngā tikanga, ka tū tonu te taumaha o te whakakaha me te whai kaha o te whare. Nō te pāpaku o te hau, me te whakaputanga mai o te hau i te pāpā hurihanga, ka taea tonu hoki te whare e whakauru kaha. Ko ngā tapa whakakaha hiko me te tapa mekanikirana kua whakatinanahia kia aukati i ngā whakamahinga hē.

kātata 70% i te rahi o te rūma hurihuri: Ko te hoahoa mariko whakapai ake i te tāone whakakaha i te tino whakauru i te mahi, ka hua ai i te kaiwhakauru kauta kauta e mahi pakari, haumaru hoki. Tiaki 70% wāhi ki te whakauru hurihuri hau. Ko te whakauru anō ki te rūma hurihuri kei te māmā. He iti noa te utu mō te whenua o te kauta.

Whakauru māmā / Utu whakahaere me te whakatika iti: Ka taea ngā pānewa ki te waenganui te wehe mā te whakatika kāore he huringa i ngā pānewa e tata ana, e whakanui ake ana i te wā tono.

Environmental Conditions of Use.png

Te tōaitanga o te hau: +45℃

Te itinga o te hau: -25℃

Te tōaitanga o te hau i ia rā: +35℃

Ahuru: Te uara o ia rā o te ahuru: ≤95%, Te uara o te marama o te ahuru: ≤90%. Te uara o ia rā o te pēhi wai: ≤2.2×10-3MPa, Te uara o te marama o te pēhi wai: ≤1.8×10-3MPa

Te teitei: ≤1000m

Kāore i te nuinga o te hau i te pāpaku e pakaru ai i te kōpua, hau, ngā kōpae whakakaha, ngā kōpae rāwekenga, ngā kōpae ranei.

Ngā Tīwae Whakahaere Motuhake:

Ka taea hoki e te hua te whakamahi mo ētahi tikanga ratonga motuhake.

Ki te eke atu ngā tikanga ratonga i runga i ngā tikanga ratonga tūmatanui, e wātea ana i waho i te tauā GB 11022 me te IEC 62271-1, mā te whakapā atu ki GP i mua kia whakamōhiotia:

Te tiketike ake i te 1000m.

Te wera ake o te taiao.

Te makariri ake o te taiao.

Ētahi atu tikanga taiao motuhake.

详情页1.jpg详情页2.jpg详情页3.jpg

Contact Us.png

Kei te whakarato a GreenPower i ngā whakaeke hiko toa. Whakapā atu ki a mātou inaianei kia rite ki te whakamātau me te tātata utu. Ko tā mātou kapa toa ka whakarato i a koe i te ratonga katoa me te tautoko hangarau i te rohe o te huringa.

Īmēra: [email protected]

Waea: +86-18989782765

Tākupehi: 057785500968

Whiwhi Kupu Tāpiri

Ka whakapā atu tā mātou kaitakawaenga ki a koe i mua.
Īmēra
Mobile/WhatsApp
Ingoa
Ingoa Kamupene
Kōrero
0/1000