GPN1 12kV Tonoa Tāpapa Whakamau Kauta
Ko te taputapu hou a GPN1-12kV e wehea ana te hiko hiko (poto noa iho ki te paparorohiko i raro nei) he hua hou, i whanaketia hoki e mātou, i runga i te tautohe i ngā tikanga hou o te ao ki te whananga me te hanga. Ko te paparorohiko e whakamahia ana ki te 3.6 ~ 12kV 3phase AC 50Hz ipu mō te whiwhi me te whakarato hiko, me te whakahaere, te arotake me te tiaki anō hoki. Ka taea te whakarite i te paparorohiko kotahi, te paparorohiko wehenga kotahi, te paparorohiko wehenga kotahi rānei. Kei te ōrite ki te IEC298 “AC Metal Enclosed Switch and Control Equipment above 1kV and below 52kV”, IEC 694 Tikanga Tuarā “Common Clauses for High Voltage Switchgear”, DIN. VDE “AC Switchgear at Rated Voltage Above 1kV”, GB 3906 “3 ~ 35kV AC Metal Enclosed Switchgear” me ētahi atu. E whai ana i te āhua pai me te whakauru tūturu ki te aukati i ngā hapa whakahaere.
- Tirohanga
- Ngā Mea Whakamomori
Ko te taputapu hou a GPN1-12kV e wehea ana te hiko hiko (poto noa iho ki te paparorohiko i raro nei) he hua hou, i whanaketia hoki e mātou, i runga i te tautohe i ngā tikanga hou o te ao ki te whananga me te hanga. Ko te paparorohiko e whakamahia ana ki te 3.6 ~ 12kV 3phase AC 50Hz ipu mō te whiwhi me te whakarato hiko, me te whakahaere, te arotake me te tiaki anō hoki. Ka taea te whakarite i te paparorohiko kotahi, te paparorohiko wehenga kotahi, te paparorohiko wehenga kotahi rānei. Kei te ōrite ki te IEC298 “AC Metal Enclosed Switch and Control Equipment above 1kV and below 52kV”, IEC 694 Tikanga Tuarā “Common Clauses for High Voltage Switchgear”, DIN. VDE “AC Switchgear at Rated Voltage Above 1kV”, GB 3906 “3 ~ 35kV AC Metal Enclosed Switchgear” me ētahi atu. E whai ana i te āhua pai me te whakauru tūturu ki te aukati i ngā hapa whakahaere.

| Pūtāuta e pā ana | 6~12kV |
| Tihoni waewae | 50\/60hz |
| Tihoni whakariterite | 630~4000A |
| Te kaha o te kaiwhakauru matua | 1250, 1600, 2000, 2500, 4000A |
| Te kaha o te kaiwhakauru tātari | 630, 1250, 1600, 2000, 2500, 3150A |
| Kaha tāpokai (4s) e taea ana | 16, 20, 25, 31.5, 40, 50kA |
| Kaha taitea taitea | 40, 50, 63, 80, 100, 125kA |
| Wāhi tapu | Kōwhiti IP4X, IP2X (kuata VCB kua whakatuwhera) |
| Te āhua ake (Whānui × Pakaru × Teitei) | 650(800, 1000)×1500(1300, 1670, 2000)×2300mm |
| Whakaaetanga | Ka tutuki i ngā tānagata haumaru o te ao pērā i te ISO, IEEE |

1) Ka taea te whakamahi i tēnei hua mō tō mātou ake GPVN-12kV whakauruhia, whakawātea ranei ringaringa koreutu ringaringa ringaringa koreutu ranei ABB o VD4 ringaringa koreutu.
2) Ko tā mātou whirwiri GPVC huihuinga hau pumau - pāpaku rānei, he VC huihuinga hau pumau a te kamupene ABB, ka taea hoki
ka hangaia e te kiamupene F-C, kia rite ki te tūhononga hauora o ngā kaha waihanga me te hiahia o ētahi atu umanga me ngā kamupene hōu.
3) Whakamahia te paparorohiko paparorohiko kounga nui huri noa i ngā taputapu CNC whakaputahia ki te kaihuinga ki te kātaha, me te whakamahi i te tikanga pōkai tuarua, te whakapakari ake i te kaha o te kātaha.
4) Te matau tuanui ki te tikanga tātai pātītī rāpoi epoxi, te here i te pāpaku, te whakapai ake, te pakanga, me te pakaru pakaru.
5) Ko te hanganga kātaha kua whakamahia katoa te whakauru, kua wehewehe katoa ngā wāhanga. Ina tāwhaihia te tuanui, ka taea te whakahaere i te tātari hiko me te whakauru tātari.
6) Ko te tikanga o te tarau tarau tarau, ka tūtohu i te trolley ki te pai rawa te whakakapi.
7) Ko te tātai tuatahi e rite ana ki ngā hiahia maha o ngā kaiwhakamahi, ā, ka taea hoki te tātai trolley tuarua.
8) Ko te tātari tātari tere hei whakauru hoki me te pakaru poka, me te tātari anō hoki (Motorized).
9) Ko te tikanga whakamaru "Rimu Whakamaru" ngawari ka taea te whakati i te whakamusage me te whakapau e noho haumaru ana i te kaimahi.
10) Ko te tapa taura he mea anamata, kei runga ake i te wāhanga pātoka, te wāhanga pātoka hau parurenga, ā, kei te wāhanga kaiwhakauru kawhe kua whakaurua ngā taputapu whakawātea i te pēhi.
11) E whai wāhi nui ana te wāhanga kawhe, ka taea te tāwhai tere ki te maha o ngā kawhe, ā, ka whakapau te teitei o te tāwhai kawhe.
12) Te tikanga whakamaru tino kaha (IP4X), kia whakati i te urupare atu rānei i ngā koiora.
13) Ko te pūnaha tuarua e wātea ana e whai ana i te taputapu whai mōhio e whai pūnaha whaiwhakaaro, whakawhitinga rara, rorohiko tūmatanui, kia taea ai te whakahaere tawhiti, te whakawhiti rara tawhiti, te tirohanga tawhiti, te tautuhi tawhiti.
14) Orau te whakarite ki ngā tātai GB3906, GB / T11022, DL404 me IEC60298, IEC62271-1, ā, kua oti te whakamātau whaitua me te whakamātau pāpaku (3000 m).
15) Kua whakawātea ngā whakamātau tōiriiri i te whare whakamātau taputapu whakapāwhara teitei.

Te āhuarangi o te wā: -25 ℃ ~ + 45 ℃, te tau ā-rā: ≤35 ℃
Te teitei: 1000m(Standard); ka taea hoki e 4500m mō ngā utu motuhake
Te pouri: tātata o te rā ≤95%, tātata o te marama ≤90%
Te kaha o te rū whenua: ≤8 kaha
Ko ngā wāhi e hāngai ana me kore e noho i ngā mea āwhata, whakapōkai, whakapōkai, me te rū kaha.




Kei te whakarato a GreenPower i ngā whakaeke hiko toa. Whakapā atu ki a mātou inaianei kia rite ki te whakamātau me te tātata utu. Ko tā mātou kapa toa ka whakarato i a koe i te ratonga katoa me te tautoko hangarau i te rohe o te huringa.
Īmēra: [email protected]
Waea: +86-18989782765