Tauwhiroa hapa

Whārangi Tīmatanga >  Ngā Hua >  Raihana Whakauru Hiko Whakarewa >  Raihana Whakamau Hau

GPN1 24kV Tonoa Tāpapa Whakamau Kauta

Ko te GPN1-24kV tapawhā AC tāwhai huinga (pāpāhi māmā hei whakarāpopoto) he hua hōu, i āhu whakapūmau ai mātou, i te whakauru i ngā tikanga matua me te hanga hanga hau teitei.

  • Tirohanga
  • Ngā Mea Whakamomori

Ko te GPN1-24kV taputapu hokoohanga hiko hiko (poto noa i runga i te pāneli) he hua hou, i whanaketia me te hoahoa e mātou, i runga i te whakauru i ngā hoahoa hoki tikanga hanga hoki kei waho i te whenua. Ko te pāneli e whakamahia ana ki te 3.6~24kV, 3phase AC 50Hz, 60Hz ranga hoki kaha, hoki hoki kaha, hoki whakahaere, whai mōhio, hoki whakamaru. Ka taea e ia te whakarite i te tātā ake, te tātā ake. Kei te tika ki te IEC298 "AC Metal Enclosed Switch and Control Equipment above 1kV and below 52kV" IEC 694 "Standard Common Clauses for High Voltage Switchgear", GB3906 "3~35kV AC Metal Enclosed Switchgear" DL404 "Order Specification for Indoor AC High Voltage Switchgear", DIN, VDE0670 "AC Switchgear at Rated Voltage Over 1kV" me ētahi atu anō hoki. E whai ana i te whakamaru tūturu me te whakamātau ki te whakauru.

Technical Parameters.png

Pūtāuta e pā ana 24kV
Tihoni waewae 50\/60hz
Tihoni whakariterite 630~4000A
Kaha tāpokai (4s) e taea ana 20/25/31.5kA
Kaha taitea taitea 50/63/80kA
Wāhi tapu Kōpaki: IP4X, tata ki te tata: IP2X
Te āhua ake (Whānui × Pakaru × Teitei) 1000(800)×1820(1500)×2430(2300)mm
Whakaaetanga Ka tutuki i ngā tānagata haumaru o te ao pērā i te ISO, IEEE

Product Features.png

Ko te kōhanga katoa i hangaia ki te kiriuta hinu hiriwa-aluminium, i whakamahia ai te mīhini CNC me te maha o ngā kinko, rahi tāuru tere, pōturi whakangao, kaha mekameka, ā, āhua pai hoki.

Ka wehewehea te anga kārika ki te kārika CB, te kārika PT, te kārika ine, me ētahi atu. Kei te kārika e rua ngā tūranga: te tūranga wehenga/whakamātau me te tūranga mahi, e hiahiatia ana kia mau tonu te kārika ki tētahi wāhi ina tū ana ki tētahi tūranga. Ko tētahi rārangi arataki motuhake kei te kōhanga CB hei āwhina i te kārika kia neke haere i waenganui i ngā tūranga wehenga/whakamātau ki te tūranga mahi. Ko te papa arai e kīia nei i te kiriuta ārai e mau ana ki te tāmoko o te kōhanga kārika.

Ko te papa paku e kawea mai i tētahi kōpaki ki tētahi atu kōpaki ki raro i te tautoko a te pōro whakawhitinga, ā, kōwhiringa ki te pouaka whakapā atu anō hoki ki te pātī paku. Ko te papa paku matua me te papa paku waenganui he paku parakoretā pōro me te tātata tapawhā hui.

Ko te kaihuri iho i te kaha me te aratū ake i te whenua e taea ngā whakaputu ki te pāpaku tuarā o te wāhi kawe kabel. Ko te kaiwhakamātau i te pōturi me te kaihere ake i te tāwhiri e taea ngā whakaputu ki roto iā ia. Ko te wāhi ine mā ngā kaihuri, ngā ine pūkaha, te tohu whakapāpaku hoki me ngā taputapu anotiria e whai tikanga ana. Ko ngā ara hurihanga kaha e takotoria ana ki te kōpaki tātā me te wāhi whanui e tino pai ana me te pōro parakoretā.

Environmental Conditions of Use.png

Te āhuarangi o te wā: -25 ℃ ~ + 45 ℃, te tau ā-rā: ≤35 ℃

Te teitei: 1000m(Whakaritenga), ka taea e 4500m te hāere mō te ota motuhake

Te pouri: tātata o te rā ≤95%, tātata o te marama ≤90%

Te kaha o te rū whenua: ≤8 kaha

Ko ngā wāhi e hāngai ana me kore e noho i ngā mea āwhata, whakapōkai, whakapōkai, me te rū kaha.

详情页1.jpg详情页2.jpg

Contact Us.png

Kei te whakarato a GreenPower i ngā whakaeke hiko toa. Whakapā atu ki a mātou inaianei kia rite ki te whakamātau me te tātata utu. Ko tā mātou kapa toa ka whakarato i a koe i te ratonga katoa me te tautoko hangarau i te rohe o te huringa.

Īmēra: [email protected]

Waea: +86-18989782765

Tākupehi: 057785500968

Whiwhi Kupu Tāpiri

Ka whakapā atu tā mātou kaitakawaenga ki a koe i mua.
Īmēra
Mobile/WhatsApp
Ingoa
Ingoa Kamupene
Kōrero
0/1000