Ngā Wāhanga Whakamau

Whārangi Tīmatanga >  Ngā Hua >  H.V. Witi Kaiwhakawhitinga >  Ngā Komupene Whakamāmā

GPN24-170P/280-3 24kV Kōpae tuanui

Ko tā mātou Wall Bushing tikanga whānui 24kV hei hoahoa mō te wehe kable tūpono me te uaua ake i ngā paretē i ngā tono hautekura. Ko tēnei putonga he pai hoki te ārai, te tautoko hangarau, me te tiaki i ngā āhuatanga taiao, kia pūmau te mahi me te haumātanga. Mā te hoahoa āwhina, ko tēnei hua he pai mō te whakamahi i ngā pūhiko, ngā taputapu hiko, me ngā pūnaha hiko a te ahumahi, e tuku ana i te ara haumaru me te haumaru mō ngā kawhe e taraiwa ana i ngā arataga.

  • Tirohanga
  • Ngā Mea Whakamomori

Ko tā mātou Wall Bushing tikanga whānui 24kV hei hoahoa mō te wehe kable tūpono me te uaua ake i ngā paretē i ngā tono hautekura. Ko tēnei putonga he pai hoki te ārai, te tautoko hangarau, me te tiaki i ngā āhuatanga taiao, kia pūmau te mahi me te haumātanga. Mā te hoahoa āwhina, ko tēnei hua he pai mō te whakamahi i ngā pūhiko, ngā taputapu hiko, me ngā pūnaha hiko a te ahumahi, e tuku ana i te ara haumaru me te haumaru mō ngā kawhe e taraiwa ana i ngā arataga.

● Whakakaha Tūmatanui: E tuku ana i te pāpāhiko e rāwekia ana e 24kV, e aki ai ngā hara hiko me te pupuri i te takotoranga o te punaha.

● Kākahu Pakari me te Manawa Atawhai: Kua hangaia mai i te karaihe ōrite silicone teitei, i te EPDM rānei, kua hoahoa tēnei hua kia pakari ki te kōpū, ki te wā pōroto, ki ngā tikanga taiao hoki e tino here ana.

● Hoahoa Āwhina: E wātea ana i ngā rahi rerekē, ā, ka taea te whakaritenga kia rite ki ngā hiahia rerekē mō te tūhuratanga, e tuku ana i te maruaroa mō ngā kaupapa rerekē.

● Tūhuratanga Māmā: Hei āhuatanga tētahi hoahoa e taea ai te tūhura māmā, he mea pai mō ngā tūhuratanga hou, me ngā punaha kei te wāhi.

● Te Tawhiti Pai o te Ara Rere: Whakaritea ana i te whakamātau tino pai, ka whakaitia ai te mōrearea o te rere aunofo ki ngā taiao waho, pērā i ngā taiao kūkū.

● Mātukutuku ki te Koroi me ngā Tōkiri: He tino pai mō ngā whakaurunga waho, ā, he manawaaki ki te korero o te taiao me ngā titaha mekanikai.

● Māma Ngaere Kabel me te Tāwhai: I hoahoaia mō te whakauru kabel tūpono me tētahi arataki rūpahu e whakarāpopoto ana i ngā wāhi pakaru, e whakarite ana i te haumāta.


Ko te tahumaero raupapa: 24kV

Te matapae: Parahi epoxy

Ko te ahauroa manaakitia: 68kV/1min

Ko te rere paraire: 26.4kV ≤3pc

Te tikanga hanga: APG (Automatic Pressure Gelation)

Te paerewa e taea ai: IEC

Te tiwhikete: CE
详情图1.jpg详情图2.jpg

Application.png
● Ngā Puna Hiko me ngā Tuarangi Tohatoha Hautō: He tino pai mō te whakauru kabeli haumaru i ngā puna hiko hautō me ngā tūhura tohatoha hiko.

● Ngā rākau hiko whakarato: He tino pai mō te whakamahi i ngā pūnaha tuku me te tukatuka, e tuku ana i te whakamarie tere mō ngā kauhanga kabeli.

● Ngā rākau hiko o ngā umanga: He tino pai mō ngā papa whakaputa ahumahi me ngā wheare e here ana i te whakamarie hautō me te kati kabeli.

● He haumaru ake: E tuku ana i tētahi ara haumaru me te tino whakapono mō ngā kawhe, e aki ai i ngā hapa hiko me te tiaki i te haumaru o te pūnaha.

● Tūtohu Roa: Hangaia mai i ngā matēria tikangia, ko tēnei pāpaku i hangaia kia roa te ora, ā, āno hea i ngā taiao uaua rawa.

● Rāwekenga Rahi: E wātea ana i ētahi rahi rerekē, e tiakina ai kia ōrite ki ngā here herenga motuhake o tō kaupapa.

● Whakauru Māmā me te Tiaki: Te whakamahi māmā me ngā hiahia iti hei whakamātau, ā, he whakangāhau i te wā me te whakamānu i ngā utu.

Contact Us.png

Ko GreenPower e whakarato ana i ngā pumanawa whakaeke hōu. Whakapā atu ki a mātou inaianei kia rite ki te whakamātau me te tātata. Ko tā mātou kapa matua ka whakarato i a koe i te ratonga katoa me te tautoko hangarau i te ao o te kaupapa.

Īmēra: [email protected]

Waea: +86-18989782765

Tākupehi: 057785500968

Whiwhi Kupu Tāpiri

Ka whakapā atu tā mātou kaitakawaenga ki a koe i mua.
Īmēra
Mobile/WhatsApp
Ingoa
Ingoa Kamupene
Kōrero
0/1000