GP-SF6-24/198.5 24kV Kōpae urunga

Ko te SF6-24/198.5 24kV Inlet Insulator he wāhanga ārai tuatahi i hoahoaia mō te 24kV-class SF6 taputapu tīwae āhuarangi āhuarangi / RMU me ngā taputapu waenga-hiko. E tuku ana i tētahi aratā ārai kua ākiaki ai mō te hononga kawhe/papa tūpono e uru mai ana, e whakarite ana i te mahi dielectric pūmau me te tautoko hinuwhiu pūmau ki te wāhi uru mai o te papamuri.

  • Tirohanga
  • Ngā Mea Whakamomori

Ko te SF6-24/198.5 24kV Inlet Insulator he wāhanga ārai tuatahi i hoahoaia mō te 24kV-class SF6 taputapu tīwae āhuarangi āhuarangi / RMU me ngā taputapu waenga-hiko. E tuku ana i tētahi aratā ārai kua ākiaki ai mō te hononga kawhe/papa tūpono e uru mai ana, e whakarite ana i te mahi dielectric pūmau me te tautoko hinuwhiu pūmau ki te wāhi uru mai o te papamuri.

Hangaia me te rāpaki epokihī kaha-teitei me ngā tohu metara kotahi (e ai ki te hoahoa), ka tautoko tēnei inlet insulator i te whakaurunga tūmatanui, ka whakaiti i te whākerenga hononga, ā, ka āwhina ki te pupuri i te pānga pāwhe roa-roa ki ngā hanganga SF6 switchgear iti.

Hoahoa mō te SF6 24kV Switchgear Inlet Interface
Whanaketia mō ngā hanganga panui SF6 iti kia pono ai te pāwhe haumaru ki te wāhi hono urupare.

Tinana Rāpaki Epokihī Kaha-Teitei
Kaha me te tūponotanga otinga tino pai mō te ratonga tūmau roa-roa ki ngā switchgear MV.

Mahi Tūtata Dielectric
Ka āwhina ki te whakaiti i te takotoranga kirima hiko, ā, ka tautoko i te pānga pāwhe tūmatanui ki te arataki tuarangi.

Ngā Tohu Metara Kotahi / Terminal (E ai ki te Hoahoa)
Whakarato pakanga haumaru me te whakawhitinga hiko tūpono, ka pai ake te āhua i te whakauru me te tiaki.

Tāpahi Pūtōrino mō te Tūwāhi Tika
Ko te turanga pūtōrino me ngā ruwha pakanga e whakaratohia ana te huinga tika me te pakanga ātaahua ki roto i te takotoranga taputapu.

Whakakapi e Teitikanga Mātātoko
He tika mō te tuku waehe, te whakakapi tiaki, me ngā kaupapa hou i ngā punaha SF6 RMU/LBS.

Te Whanaketanga ā-Tuhi
Ka taea te tuku i ngā rahi, tikanga tohu, tohu, me te whakauru kōpaki mā te tuhinga mō ngā hiahia OEM me ngā ritenga hou.


Ko te tahumaero raupapa: 24kV

Te matapae: Parahi epoxy

Te tikanga hanga: APG (Automatic Pressure Gelation)

Te paerewa e taea ai: IEC

Te tiwhikete: CE

详情图1.jpg详情图2.jpg详情图3.jpg详情图4.jpg

Application.png
epeni RMU/LBS 24kV SF6 hepari huangongo (takotoranga puhipuhi urupare)

te wāhi tūmata o mua o te taputapu pakaru uta 24kV SF6 load break switch

Taputapu tukatuka tokomaha waenga e hiahiatia ana i ngā waehe tūmata o mua iti

Whanaketanga OEM, waehere whakakapi, whakapai ake me te whakakapi mō ngā punaha SF6-24