GPVN 36kV 40.5kV Kaitiaki Arau Kauta Kaiwhakamau
Ko te kaiwhakawhitinga hiko GPVN-40.5kV indoor vacuum he hua e hoahoa ana me te whanangia e tātou kamupene me te Xi’an High-voltage Electric Apparatus Institute. Ko te VCB he whakarewa hiko 40.5kV, tapawhā, AC 50/60Hz. Ka whakamahia ki ngā kamupene hōhonu, whare hiko me te whare hiko tuarua hei tiaki me te whakahaere i ngā taputapu hiko. Ka taea hoki e te whakamahia ki ngā wāhi e whakahaerehia ana katoa.
- Tirohanga
- Ngā Mea Whakamomori
Ko te kaiwhakawhitinga hiko GPVN-40.5kV indoor vacuum he hua e hoahoa ana me te whanangia e tātou kamupene me te Xi’an High-voltage Electric Apparatus Institute. Ko te VCB he whakarewa hiko 40.5kV, tapawhā, AC 50/60Hz. Ka whakamahia ki ngā kamupene hōhonu, whare hiko me te whare hiko tuarua hei tiaki me te whakahaere i ngā taputapu hiko. Ka taea hoki e te whakamahia ki ngā wāhi e whakahaerehia ana katoa.

| Pūtāuta e pā ana | 36/38/40.5kV |
| Tihoni waewae | 50\/60hz |
| Tihoni whakariterite | 630~2500A |
| Te tika o te ahi (1min) | 95kV (118, te tawhitinga wātea) |
| Te tika ake o te ahi (te tōaitanga) | 185kV (215, te tawhitinga wātea) |
| Te hua pūngao o te kuhu i te oneone | 20, 25, 31.5kA |
| Kaha hiko tautohe tautohe (taitea) | 50, 63, 80kA |
| I roa te tika (4s) | 20, 25, 31.5kA |
| Kaha taitea taitea | 50, 63, 80kA |
| Te tika wehenga o te pōtae raraunga | 400A |
| Ngā wā pātua o te kaha pātua tiriti tāpiri | 30 ngā wā |
| Ūkaipō mekanikā | 10000 wā, 20000 wā (mō te momo irirangi) |
| Whakaaetanga | Ka tutuki i ngā tānagata haumaru o te ao pērā i te ISO, IEEE |

Kei te wāhi runga te kauta whakamutu ariki ā-iriwhi, ā, kei te wāhi raro te tikanga. Ko te hanganga tōtika tēnei hei āwhina i te whakamātau.
Te hanganga whakaiti pīroiroi e whakamahi ai hau me ngā taputapu takotoranga. Iti noa te āhua me te pāpaku.
Ko te kauta whakamutu ariki ā-iriwhi a Cutler-Hammer Company (Amerika) me te ZMD tāwāhi e whai wāhi ana ki te VCB. E rua ngā momo kauta e whakamutu ai i te ariki ā-iriwhi trought te marautanga poutū ā-iriwhi, ā, he iti noa te mutunga, he pai hoki te kaha whakatuwhera me te kaha kati.
Ko te tikanga whakahaere pāpaku māmā kāore e hiahiatia ana te tūhono i roto i te 10000 o ngā whakahaerenga.
Ko te pāpaku hōke, māmā te whakahaere, he tōtika te aronga ā-whai hoki te kaha whakakaha.

| Piki Rangi | 1000m (Tuarā); e eke taea ana ki te 4500m mō te tono motuhake |
| Taurangi ā-wāhi | -25℃ ~ +45℃ |
| Te pāmahana relative | Ko te tāmata o ia rā ≤ 95%; ko te tāmata o te marama ≤ 90% |
| Kaha o te rū whenua | ≤ 8 kīraro |
| Ngā wā e tika ana | Me korekau ngā mea whakaputua, ngā mea e pakaru ai, ngā mea e kōhunuhunu ai, me te rū hohonu |



Kei te whakarato a GreenPower i ngā whakaeke hiko toa. Whakapā atu ki a mātou inaianei kia rite ki te whakamātau me te tātata utu. Ko tā mātou kapa toa ka whakarato i a koe i te ratonga katoa me te tautoko hangarau i te rohe o te huringa.
Īmēra: [email protected]
Waea: +86-18989782765