GPM2.1 Series Low Voltage Switchgear

Home >  Products >  Low Voltage Switchgear Solutions >  GPM2.1 Series Low Voltage Switchgear

GPM2.1 Enclosure Low Voltage Switchgear (Square Handle)

GPM2.1 low voltage drawer switchgear produced by GreenPower adopts standard modules and is factory assembled low voltage drawer switchgear. It is suitable for AC 50/60Hz, rated working voltage <660V, and the power supply and distribution systems rated current 6300A and below, are used for electric energy distribution, conversion, control and reactive power compensation.

  • Overview
  • Recommended Products

GPM2.1 low voltage drawer switchgear produced by GreenPower adopts standard modules and is factory assembled low voltage drawer switchgear. It is suitable for AC 50/60Hz, rated working voltage <660V, and the power supply and distribution systems rated current 6300A and below, are used for electric energy distribution, conversion, control and reactive power compensation.

GPM2.1 low voltage drawer switchgear is a control device with advanced technology, stable performance, reasonable structure, convenient use, safe and reliable. It has been widely used in power supply and distribution systems such as power generation, construction, steel, cement, mining, and petrochemical.

Technical Parameters.png

Rated voltage 380/440/660V
Rated current 630~6300A
Rated frequencty 50/60Hz
Rated peak withstand current 1pk can casue 375kA
IP degree IP30 / IP32 / IP40 / IP54
Rated insulation level 660/1000V

Product Features.png

The structure is reasonable and the technical level is high. The rated current carrying capacity, breaking capacity and dynamic thermal stability of GPM2.1 switchgear are higher than other types of low voltage switchgear, and it is easy to maintain, safe and reliable.

Good protection performance. GPM2.1 is a fully isolated switchgear, the internal compartment meets the requirements of IEC439-1 "Form 3b" or "Form 4b" as ordering, and the enclosure protection grade is IP3X, IP31, IP32, IP4X, IP41, IP42, IP43, IP5X, IP54 as ordering.

The interlock is reliable. GPM2.1's anti-misoperation interlock is jointly completed by the circuit breaker operating handle mechanism and the drawer position mechanical interlocking operating mechanism. Its design is accurate and logical, which can effectively prevent various possible misoperations and can be used with the operation mode to flexibly realize interlocking between cabinets.

There are many plans and it is complete and easy to combine. GPM2.1 takes 8E as the basic unit, and the functional units are 8E/4, 8E/2, 6E, 8E, 12E, 16E, 24E, 32E, 72E. At most 36 functional units can be arranged in one MCC cabinet, and it can be realized. The mixed installation of PC and MCC provides favorable conditions for reducing the number of cabinets and flexibly selecting solutions.

GPM2.1 low voltage drawer switchgear is a control device with advanced technology, stable performance, reasonable structure, convenient use, safe and reliable. It has been widely used in power supply and distribution systems such as power generation, construction, steel, cement, mining, and petrochemical.

详情页1.jpg详情页2.jpg

Contact Us.png

GreenPower provides professional smart switchgear solutions. Contact us immediately for free consultation and quotation. Our professional team will provide you with full service and technical support throughout the process.

Email: [email protected]

Tel: +86-18989782765

Fax: 057785500968

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Message
0/1000
Inquiry Inquiry Email Email WhatsApp WhatsApp
WhatsApp
TopTop