Vacuum Circuit Breaker

Home >  Products >  H.V. Electrical Components >  Vacuum Circuit Breaker

GPVN 36kV 40.5kV Embedded Vacuum Circuit Breaker

GPVN-40.5kV indoor vacuum circuit breaker is a product designed and produced by our company and Xi’an High-voltage Electric Apparatus Institute. The VCB is of rated voltage 40.5kV, three-phase and AC 50/60Hz. It applies to mining firms, power house and substation acting as protection and control electric apparatus. It is also applicable in occasions with frequent operation.

  • Overview
  • Recommended Products

GPVN-40.5kV indoor vacuum circuit breaker is a product designed and produced by our company and Xi’an High-voltage Electric Apparatus Institute. The VCB is of rated voltage 40.5kV, three-phase and AC 50/60Hz. It applies to mining firms, power house and substation acting as protection and control electric apparatus. It is also applicable in occasions with frequent operation.

Technical Parameters.png

Rated voltage 36/38/40.5kV
Rated frequency 50/60Hz
Rated current 630~2500A
Power frequency withstand voltage (1min) 95kV (118, isolating distance)
Lightning impulse withstand voltage (peak) 185kV (215, isolating distance)
Rated short-circuit breaking current 20, 25, 31.5kA
Rated short-circuit making current (peak) 50, 63, 80kA
Rated short-time withstand current (4s) 20, 25, 31.5kA
Rated peak withstand current 50, 63, 80kA
Rated breaking current of capacitor bank 400A
Breaking times of rated short circuit breaking current 30 times
Mechanical life 10000 times, 20000 times (for magnet type)
Compliance Meets international safety standards such as ISO, IEEE

Product Features.png

The arc-extinguish chamber is on the upper part and the mechanism is on the lower part. This structure is convenient for debug.
Complex insulating structure using air and organic material. Compact dimension and small weight.
Vacuum arc-extinguish chamber of Cutler-Hammer Company (USA) and domestic ZMD are both applicable for the VCB. Both two kinds of chambers extinguish arc by vertical magnetic field and featuring with low cut-off and good on-off capability with asymmetry.
Simple spring operation mechanism is free from maintenance within 10000 times of operations.
Lead-screw propeller, easy and stable operation and good self-locking capability.

Ambient Condition.png

Altitude 1000m (Standard), can be up to 4500m for special ordering
Ambient temperature -25℃~+45℃
Relative humidity Daily average ≤95%, monthly average ≤90%
Earthquake intensity ≤8 degree
Applicable occasions Should be free from inflammables, explosives, corrosives and severe vibration

详情页1.jpg详情页2.jpg

Contact Us.png

GreenPower provides professional smart switchgear solutions. Contact us immediately for free consultation and quotation. Our professional team will provide you with full service and technical support throughout the process.

Email: [email protected]

Tel: +86-18989782765

Fax: 057785500968

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Message
0/1000
Inquiry Inquiry Email Email WhatsApp WhatsApp
WhatsApp
TopTop