Motorized Earthing Switch GPJN15-17.5/D31.5-150(L)

GPJN15-17.5/D31.5 series indoor high voltage motorized earthing switch (short as: motorized earthing switch) is designed for the intelligent switchgear requirement of the electric system. It is suit for 3~17.5kV, 3 phase, AC 50 (60) Hz power system and kinds of high voltage switchgears. It is applicable for high voltage switchgear arrangement as the earthing protection when maintenance. The products’ performance meet GB1985-2004 High Voltage AC Disconnector and Earthing Switch and the requirements of standard as well as IEC62271-102:2002.

  • Overview
  • Recommended Products

GPJN15-17.5/D31.5 series indoor high voltage motorized earthing switch (short as: motorized earthing switch) is designed for the intelligent switchgear requirement of the electric system. It is suit for 3~17.5kV, 3 phase, AC 50 (60) Hz power system and kinds of high voltage switchgears. It is applicable for high voltage switchgear arrangement as the earthing protection when maintenance. The products’ performance meet GB1985-2004 High Voltage AC Disconnector and Earthing Switch and the requirements of standard as well as IEC62271-102:2002.

Earthing switch structure is simple and compact, light weight, flexible operation, easy installation, dynamic thermal stability, and a reliable electric operation, keep the original interlocks in catching rabbits switchgear chain constant, has been a national patent.

d315 150l-3

Rated voltage 17.5kV
Rated short-time withstand current 31.5kA
Rated short-circuit duration 4s
Rated short-circuit close current 80kA
Rated peak withstand current 80kA
Phase distance 150mm
Certificate ASTA, KEMA, CE
Compliance Meets international safety standards such as ISO, IEEE

 

Ambient Condition.png
Altitude sea level not exceeding 1000m

Ambient air temperature: +45℃, -25℃

Seismic intensity not exceeding 8 degree

Related humidity daily average value not more than 95%, monthly average not more than 90%

Pollution class: II

Special condition: Please specify when ordering.

详情页1.jpg

Contact Us.png

GreenPower provides professional smart switchgear solutions. Contact us immediately for free consultation and quotation. Our professional team will provide you with full service and technical support throughout the process.

Facebook: www.facebook.com/people/Zhejiang-Greenpower-Electric-Co-Ltd/100083901876783

Linkedin: www.linkedin.com/in/annie-chan-18631862

E-mail: [email protected]

Tel: 8618958820879 / 057785500968

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Message
0/1000
Inquiry Inquiry Email Email WhatsApp WhatsApp
WhatsApp
TopTop