GPNY40.5-320 40.5kV Insulator

The 40.5kV Insulator is designed for high-reliability insulation and mechanical support in 40.5kV-class medium-voltage switchgear and power distribution equipment. It is widely used to support and isolate live conductors, busbars, terminals, or switching devices, maintaining required clearances and insulation performance under long-term electrical and environmental stress.

  • Overview
  • Recommended Products

The 40.5kV Insulator is designed for high-reliability insulation and mechanical support in 40.5kV-class medium-voltage switchgear and power distribution equipment. It is widely used to support and isolate live conductors, busbars, terminals, or switching devices, maintaining required clearances and insulation performance under long-term electrical and environmental stress.

Depending on application, the insulator can be supplied as post insulator / bushing-type insulator / support insulator, with material options such as silicone rubber composite or epoxy resin (as per design). It is suitable for indoor panels, outdoor installations, and harsh environments where stable dielectric performance and mechanical strength are required.
gpny405 320 405kv insulator-3

40.5kV-Class Insulation Reliability
Designed to maintain stable dielectric performance for MV equipment and prevent flashover risks under rated conditions.

High Mechanical Strength for Support Functions
Provides stable support for conductors/busbars and resists bending and vibration during operation and short-circuit events (as per design).

Optimized Creepage Distance (By Pollution Class)
Creepage and shed profile can be selected based on pollution level requirements for indoor/outdoor service.

Weathering and Aging Resistance (Material-Dependent)
Composite silicone rubber provides strong UV/aging performance; epoxy resin provides rigid dimensional stability for indoor designs.

Stable Dimensional Consistency
Controlled molding process supports repeatable installation and interchangeability for OEM and maintenance replacement.

Customization by Drawing
Dimensions, mounting interfaces, inserts, markings, and color can be supplied according to drawings.

gpny405 320 405kv insulator-4
Rated voltage: 40.5kV

Material: Epoxy resin

Manufacturing process: APG (Automatic Pressure Gelation)

Applicable standard: IEC

Certificate: CE

详情图1.jpg详情图2.jpg

Application.png
● 40.5kV metal-clad / metal-enclosed switchgear

● Busbar and conductor support insulation

● VCB / disconnector compartments (support & insulation interface)

● Outdoor distribution equipment requiring MV insulation parts

Contact Us.png

GreenPower provides professional smart switchgear solutions. Contact us immediately for free consultation and quotation. Our professional team will provide you with full service and technical support throughout the process.

Email: [email protected]

Tel: +86-18989782765

Fax: 057785500968

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Message
0/1000
Inquiry Inquiry Email Email WhatsApp WhatsApp
WhatsApp
TopTop