GPNY40.5-320S 40.5kV Capacity insulator (Sensor)

The 40.5kV Sensor-Embedded Insulator combines primary insulation with condition monitoring capability for high-value MV assets. It is designed for 40.5kV switchgear and distribution systems where real-time or periodic monitoring helps improve reliability, reduce unplanned outages, and support predictive maintenance.

  • Overview
  • Recommended Products

The 40.5kV Sensor-Embedded Insulator combines primary insulation with condition monitoring capability for high-value MV assets. It is designed for 40.5kV switchgear and distribution systems where real-time or periodic monitoring helps improve reliability, reduce unplanned outages, and support predictive maintenance.

The embedded / integrated sensor module can be configured (depending on model) to monitor temperature rise, electric field, leakage current, partial discharge-related signals, or mechanical stress, providing data to support maintenance decisions. Output and integration can be tailored for local indicators, wired communication, or gateway-based monitoring as required by the project.
gpny405 320s 405kv capacity insulator sensor-3

Integrated Insulation + Monitoring in One Component
Reduces additional mounting complexity and improves monitoring point consistency.

Selectable Monitoring Targets (Model-Dependent)
Temperature / leakage current / electric-field / PD-related signals / mechanical load (as configured).

Improved Asset Reliability and Maintenance Efficiency
Enables earlier abnormal trend detection and supports condition-based maintenance planning.

Engineering-Friendly Integration
Flexible output/interface options to match protection/automation systems (wired or gateway-based).

High-Voltage Insulation and Mechanical Support
Maintains core insulation/support performance while adding sensing capability.

Customization by Drawing and System Requirements
Mechanical interfaces and sensor placement can be tailored for different switchgear layouts.

gpny405 320s 405kv capacity insulator sensor-4
Rated voltage: 40.5kV

Material: Epoxy resin

Manufacturing process: APG (Automatic Pressure Gelation)

Applicable standard: IEC

Certificate: CE

详情图1.jpg详情图2.jpg详情图3.jpg

Application.png
● 40.5kV switchgear requiring condition monitoring

● Critical feeders, industrial distribution, substations with high availability demand

● Monitoring retrofit projects (when compatible with existing layouts)

● Smart distribution systems with data collection requirements

Contact Us.png

GreenPower provides professional smart switchgear solutions. Contact us immediately for free consultation and quotation. Our professional team will provide you with full service and technical support throughout the process.

Email: [email protected]

Tel: +86-18989782765

Fax: 057785500968

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Message
0/1000
Inquiry Inquiry Email Email WhatsApp WhatsApp
WhatsApp
TopTop