Kaitiaki Hiko Hau

Whārangi Tīmatanga >  Ngā Hua >  H.V. Komponenta Hiko >  Pūmotu Hōu

GPVN 36kV 40.5kV Kaitiaki Arau Kauta Kua Whakauru

Ko te kaiwhakawhitinga hiko GPVN-40.5kV indoor vacuum he hua e hoahoa ana me te whanangia e tātou kamupene me te Xi’an High-voltage Electric Apparatus Institute. Ko te VCB he whakarewa hiko 40.5kV, tapawhā, AC 50/60Hz. Ka whakamahia ki ngā kamupene hōhonu, whare hiko me te whare hiko tuarua hei tiaki me te whakahaere i ngā taputapu hiko. Ka taea hoki e te whakamahia ki ngā wāhi e whakahaerehia ana katoa.

  • Tirohanga
  • Ngā Mea Whakamomori

Ko te kaiwhakawhitinga hiko GPVN-40.5kV indoor vacuum he hua e hoahoa ana me te whanangia e tātou kamupene me te Xi’an High-voltage Electric Apparatus Institute. Ko te VCB he whakarewa hiko 40.5kV, tapawhā, AC 50/60Hz. Ka whakamahia ki ngā kamupene hōhonu, whare hiko me te whare hiko tuarua hei tiaki me te whakahaere i ngā taputapu hiko. Ka taea hoki e te whakamahia ki ngā wāhi e whakahaerehia ana katoa.

Technical Parameters.png

Pūtāuta e pā ana 36/38/40.5kV
Tihoni waewae 50\/60hz
Tihoni whakariterite 630~2500A
Te tika o te ahi (1min) 95kV (118, te tawhitinga wātea)
Te tika ake o te ahi (te tōaitanga) 185kV (215, te tawhitinga wātea)
Te hua pūngao o te kuhu i te oneone 20, 25, 31.5kA
Kaha hiko tautohe tautohe (taitea) 50, 63, 80kA
I roa te tika (4s) 20, 25, 31.5kA
Kaha taitea taitea 50, 63, 80kA
Te tika wehenga o te pōtae raraunga 400A
Ngā wā pātua o te kaha pātua tiriti tāpiri 30 ngā wā
Ūkaipō mekanikā 10000 wā, 20000 wā (mō te momo irirangi)
Whakaaetanga Ka tutuki i ngā tānagata haumaru o te ao pērā i te ISO, IEEE

Product Features.png

Kei te wāhi runga te kauta whakamutu ariki ā-iriwhi, ā, kei te wāhi raro te tikanga. Ko te hanganga tōtika tēnei hei āwhina i te whakamātau.
Te hanganga whakaiti pīroiroi e whakamahi ai hau me ngā taputapu takotoranga. Iti noa te āhua me te pāpaku.
Ko te kauta whakamutu ariki ā-iriwhi a Cutler-Hammer Company (Amerika) me te ZMD tāwāhi e whai wāhi ana ki te VCB. E rua ngā momo kauta e whakamutu ai i te ariki ā-iriwhi trought te marautanga poutū ā-iriwhi, ā, he iti noa te mutunga, he pai hoki te kaha whakatuwhera me te kaha kati.
Ko te tikanga whakahaere pāpaku māmā kāore e hiahiatia ana te tūhono i roto i te 10000 o ngā whakahaerenga.
Ko te pāpaku hōke, māmā te whakahaere, he tōtika te aronga ā-whai hoki te kaha whakakaha.

Ambient Condition.png

Piki Rangi 1000m (Tuhinga o mua), ka taea e 4500m mō te ota motuhake
Taurangi ā-wāhi -25℃~+45℃
Te pāmahana relative Roa o te rā ≤95%, roa o te marama ≤90%
Kaha o te rū whenua ≤8 kia tahi anō
Ngā wā e tika ana Mea noa i ngā mea āwherowhero, ngā mea pātata, ngā mea whakapai ai, me ngā whakapapa pōpō

详情页1.jpg详情页2.jpg

Contact Us.png

Kei te whakarato a GreenPower i ngā whakaeke hiko toa. Whakapā atu ki a mātou inaianei kia rite ki te whakamātau me te tātata utu. Ko tā mātou kapa toa ka whakarato i a koe i te ratonga katoa me te tautoko hangarau i te rohe o te huringa.

Īmēra: [email protected]

Waea: +86-18989782765

Tākupehi: 057785500968

Whiwhi Kupu Tāpiri

Ka whakapā atu tā mātou kaitakawaenga ki a koe i mua.
Īmēra
Mobile/WhatsApp
Ingoa
Ingoa Kamupene
Kōrero
0/1000